Pressure Transmitter

model9112.GIF (1065 bytes)

Features
  • Pressure ranges: 15, 30, 50, 100, 250, 500, 1k, 1.5k, 2k, 3k, 5k, 7.5k, 10k, 15k, 20k, 30k, 40k, 50k, 60k
  • Wetted material: A286 body and 316
  • Hydrogen compatible
  • FM approved, NEMA 4
  • Three year warranty
9112.GIF (10092 bytes)
.
Performance Specifications @ 72°F (22°C)
Linearity & Hysteresis (Terminal Based) < ± 0.25% of span
< ± 0.10%  of span specify option S10
(100 thru 20,000 PSI)
Repeatability Within ± 0.08% of calibrated span
Resolution Infinite
Operating Temperature Range -13° to 185°F, (-25° to 85°C)
Compensated Temperature Range 0° to 160°F, (-18° to 71°C)
Thermal Zero Shift < ± 0.0075% F.S.O./°F (< ± 0.0135% F.S.O./°C)
Thermal Span Shift < ± 0.0075% F.S.O./°F (< ± 0.0135% F.S.O./°C)
Response Time < 3 milliseconds from 10% to 90% step change
Stability Better than ± 0.25%, 6 months
Electrical Specifications
Bridge Four active arm bonded strain gage
Current Output 4-20 mA
Current Limiting 28 mA (typical)
Supply Voltage 10 to 30 VDC, unregulated
Power Supply Effect < ± 0.005% per volt change @ 100% of calibrated span
Zero Adjustment ± 3% of span
Span Adjustment ± 5% of span
Loop Resistance 0 Ohms @ 10 VDC to 1000 Ohms @ 30 VDC
Circuit Protection Reverse polarity protection
Insulation Resistance 1000 Megohms min. @ 50 VDC to transmitter case
Hazardous Classification (option IS) "FM" intrinsically safe with entity approval for class I, II and III DIV 1, Groups A, B, C, D, E, F, and G. "FM" file number 3R5A9.AX (3610)
Transmitter Output Parameter Vmax = 30V, Imax = 200 mA, Ci = 0.052 µF, Li = 0.0 mH
Mechanical Specifications           Dimensional Outline Drawing
Pressure Ranges 15, 30, 50, 100, 250, 500, 1k, 1.5k, 2k, 3k, 5k, 7.5k, 10k, 15k, 20k, 30k, 40k, 50k, 60k
Proof Pressure 150% F.S. without exceeding specified tolerance
Option S4 120% F.S. without exceeding specified tolerance
Option S6 10 times F.S. without exceeding specified tolerance
Burst Pressure 15 thru 50 PSI: 500 PSI
100 thru 100k PSI: 4 times F.S. or 150k PSI, whichever is less
Option S4 2 times F.S.
Option S6 15 thru 50 PSI: > 1000 PSI
Wetted Material A286 body and 316; Nitronic 50 process connection, hydrogen compatible
Option S2 A286 body and 316; Nitronic 50 process connection, sour gas compatible meets NACE MR0175 latest revision
Option S4 Hastelloy® C-276 body and process connection, sour gas compatible meets NACE MR0175 latest revision
Weight 25 ounces approximately
Environmental Classification FM approved, NEMA 4
Process Connections
15 thru 10,000 PSI 1/4-18 NPT Male
MS-33649-04
1/2-14 NPT Male
250 thru 10,000 PSI 1/2-14 NPT Female
250 thru 60,000 PSI F250C
Specifications are subject to change without notice. Transducer is supplied with NIST traceable certificate of conformance.  13 point calibration certificate is also available.