| Accuracy @ 25°C |
|
|
Maximum
Error |
± 0.05%
of reading ± 1 count |
|
Zero
Tempco |
± 0.01%
of offset/°C |
|
Span
Tempco |
± 0.02%
of reading/°C |
|
Full
Scale Step Response |
1 second |
|
Warm-up
to Rated Accuracy |
30
minutes |
| Noise Rejection |
|
|
NMR, SIG
HI to SIG LO |
56 dB, 50
to 60 Hz |
|
CMR, SIG
LO to PWR GND |
120 dB,
50 to 60 Hz |
|
CMV, SIG
LO to PWR GND |
1500 Vp
per HV test, 354 Vp per IEC spacing |
| Analog to Digital Conversion |
|
|
Technique |
Dual
slope, average-value |
|
Signal
Integration Period |
100
millisecond |
|
Read Rate |
2.5/second |
| Transmitter Excitation Supply |
|
|
Output
Voltage |
Selectable
10 or 24 VDC |
|
Output
Current (max) |
30mA at
10 V, 20 mA at 24 V |
|
Line
Regulation |
±
0.01%/V of AC power |
|
Load
Regulation |
± 0.5% |
|
Tempco |
±
0.02%/°C |
|
Ripple at
50/60 Hz |
± 0.01% |
| Display |
|
|
Type |
7
segment, LED (Red) |
|
Decimal
Points |
Three
position jumper selectable |
|
Over
range indication |
Three
least significant digits blank |
| Power Options |
|
|
AC
Voltage |
24, 100,
115 or 230 VAC ± 15% @ 2 watts 49-63 Hz |
|
DC |
7-32 VDC
Non-isolated |
| Electrical Connections |
|
|
Power
and Signal Input |
|
|
With
Transducer Excitation |
Without
Transducer Excitation |
|
AC
power |
DC
Power |
|
1 Signal
high |
1 Signal
high |
|
2 Signal
low |
2 Signal
low |
|
3 + Exc. |
3 Hold |
|
4 - Exc. |
4 Digital
ground |
|
5 AC
ground |
5 - DC |
|
6 AC low |
6 + DC |
|
7 AC high |
7 No
connection |
| Environmental |
|
|
Operating
Temperature |
0° to
60°C |
|
Storage
Temperature |
-40° to
85°C |
|
Relative
Humidity |
95% at
40°C, non-condensing |
| Mechanical |
|
|
Dimensions |
3/64 DIN
size front panel 0.94" H x 2.84" W x 4.6" D (24 x 24 x 117mm) |
|
Panel
Cutout |
0.87"
x 2.68" (22.2 x 68mm) |
|
Case
Material |
94V-1 UL
rated Noryl SE-1 |