| A to D Conversions |
|
|
Technique (Pat. 5,262,780) |
Concurrent Slope |
|
Rate |
60/s at 60Hz operation
50/s at 50Hz operation |
|
Output Update Rate |
56/s at 60Hz, 47/s at 50Hz |
|
Display Update Rate |
3.5/s at 60Hz, 3/s at 50Hz |
|
Analog Output Response Time |
17ms |
| Accuracy @ 25°C |
|
|
DC volts, Amps, ratio |
0.01%FS ±1 count |
|
Strain Gage Meter |
0.01%FS ±1 count |
|
Span Tempco |
|
|
|
Process Input |
0.003% of reading/°C |
|
|
Strain Gage Meter |
0.0015% of reading/°C |
|
Zero Tempco |
0.1 counts/°C |
| Noise Rejection |
|
|
CMV from DC to 60Hz |
Safety rated to 250 VAC 4.2kVp per high voltage test |
|
CMR from DC to 60Hz |
130 dB |
|
NMR to 50/60Hz line |
90 dB with minimum filtering |
| Environmental |
|
|
Operating Temperature |
0° to 55°C |
|
Storage Temperature |
-40° to 85°C |
|
Relative Humidity |
95% at 40°C, non-condensing |
|
NEMA 4X |
When panel mounted |
| Operating Power |
|
|
Voltage (standard) |
85 to 264 VAC, 90 to 370 VDC |
|
Voltage (optional) |
8-28 VAC, 9 to 37 VDC |
|
Frequency |
DC and 47 to 440Hz |
| Excitation Power Supplies |
|
|
Outputs |
5 VDC, 5%, 100mA max
10VDC, 5%, 120mA max
24VDC, 5%, 50mA max |
|
Isolation (power gnd) |
Safety-rated to 250VAC, 4.2kVp per high voltage test |
| Display |
|
|
Type |
5 digit LED, 7 segment, 14.2mm (0.56) high digits and 3 LED
indicators |
|
Color |
Red |
|
Range |
-99999 to 99999 and -99990 to 99990 |
| Dimensions |
|
|
1/8 DIN size front panel |
1.89(H) x 3.78(W) x 4.02 (depth behind panel) (48 x 96 x
102mm) |
| Panel Cutout |
|
|
1.772 +0.024/-0 x 3.622 +0.032/-0 (45 +0.6/-0 x 92
+0.8/-0) |