Single or Dual Channel Digital Indicator |
00 | |
Features
|
![]() |
|
| . | ||
Autotare
This function allows the user to set the selected display/input to zero. It can be
performed via a front panel key or remote input. Setup is available to switch the display
from net to gross.
Net/Gross
The net value or the gross value can be displayed via a front panel key or remote input.
Alarm limits, analog out or peak values may be assigned to the net or gross values.
Selectable Resolution
/ Sampling Rate
This unit has a selectable display resolution. You can select either 4 1/2 or 5 1/2 digit
resolution both with an update rate of 60/sec.
Fine Offset
This allows for a direct zero offset to be programmed to compensate for system setups and
changes.
Fine Scale
This allows for a direct correction of the span value without recalibrating.
20 Point
Linearization
U-plot 20 point linearization allows the user to program up to 20 known values of
nonlinear curvature along with the corresponding display readings. Typical uses are
improved lineararity of transducers, load cells, etc. and for display of volume in
irregularly shaped storage vessels.
Peak 1 and Peak 2
Peak 1 and peak 2 are both assignable to capture the maximum or minimum display value.
They are assignable to any channel and the net or gross value.
Math Channel
The 4100 comes with an extra channel that is a non input channel. This can be used to
duplicate an input channel for completely new scaling and alarm setups. The two channel
input model 4100 can be used to perform A + B, A B or A x B math functions.
(Consult Precise Sensors Inc. for your special equations)
Second Scale
This function allows the user to set a second scaling to the input. The input will then be
displayed in two engineering units (typically for English/Metric displays). Scale2 is
setup by entering the input low and high values and corresponding display values.
Alarms
Each meter is standard with 4 programmable alarms that control the front panel LED status
and the one standard relay and optional 3 relay outputs.
Each alarm is:
Relay Output
1 Form A relay 240VAC@5A, is provided standard for use as an alarm output or shunt cal
relay.
Dummy Zero
Available soon
| . |
| Specifications |
Accuracy |
0.02% |
|
Zero Drift |
0.02% |
|
Span Drift |
10 ppm/°C |
|
Over-range Capability Minimum |
10% |
|
Normal Mode Rejection Ratio |
63dB |
|
Common Mode Rejection Ratio |
130 dB |
|
Response Time |
100 msec max to display (10 updates / sec) |
|
Internal Resolution |
22 bits |
|
Conversion Time |
17 ms in 4 1/2 digit and 5 1/2 digit mode |
|
Digital Filter |
60 Hz in 4 1/2 digit and 5 1/2 digit mode |
|
Warm Up Time |
15 minutes |
|
Operating Temp Range |
-20°C to 60°C |
|
Storage Temp Range |
-20°C to 85°C |
|
Humidity |
to 95%, non-condensing |
|
AC Supply Voltage |
85 to 265 VAC |
|
Power Consumption |
15 Watts maximum |
|
Isolation |
|
|
|
Signal Input to Earth Ground | Safety rated to 450 Vrms, 2200 Vp high voltage test |
|
Option board to Earth Ground | Safety rated to 450 Vrms, 2200 Vp high voltage test |
|
Option board to Signal Input | 400 Vp |
|
Power to Earth Ground | Safety rated to 500 Vrms, 4000 Vp high voltage test |
Weight |
0.84 lbs. |
|
Dimensions |
W4.13" x L5.12" x H2.30" |
|
| Panel Cutout | 1.72" x 3.55" | |
| Specifications are subject to change without notice. |
| . |
| Options |
Option D: 3 each form C (single pole double throw) relays rated at 5 amp @ 240VAC, 5 amps @ 30VDC.
Option F: Excitation output voltage supplies (jumper selectable) 5VDC @ 40mA, 24 VDC @ 50mA, +15 VDC @ 200mA /supply, 10 VDC @ 200mA supply.
Option H: Analog output 0-5 VDC, 0-10 VDC, +5VDC to -5 VDC, 4-20mA, 0-20mA (Available soon)
Option K: Screw terminal connectors
Set up service: Factory scaling calibration (user provides input range and display range.)