Process and Strain Gage Digital Indicator |
00 | |
Features
|
![]() |
|
| . | ||
Autocalibration/Load Calibration
This function allows user to setup meter with known/calibrated inputs. Low signal input is
applied and the value desired on the display is entered. High signal input is applied and
the value desired on the display is entered - setup is complete!
Square Root
Square root linearization is available for flow measurement.
Peak/Valley Display
Two independent memory storages. Front key for selection and reset. Adjustable capture
width from.1 to 120 seconds. Selection of gross or net values.
Autotare Function
Autotare function offers the user the capability to set the reading to zero, storing the
tare value. This function is performed by pushing a front push button. A command is
available to switch the reading from net to gross.
Password Protected
Multilevel password to prevent the operator from setup calibration alteration, setpoint
setting, peak reset.
Factory Setup
A special function allows the user to restore the factory setup configuration.
| . |
| Measuring Ranges |
4000P Process Signals Input Measuring Range |
|||
Input |
Measuring Range |
Display Range |
Accuracy |
Current |
0-20 mA |
-1999 to 9999 |
±0.05% |
Voltage |
0-10V |
-1999 to 9999 |
±0.04% |
4000S Load Cells and Strain Gage Input Measuring Range |
|||
Input |
Measuring Range |
Display Range |
Accuracy |
| Voltage | From ±30.00 to 120 mV f.s. | -1999 to 9999 | ±0.04% |
| . |
| Specifications |
4000P Volt Input |
|
Input Range |
0-10V, 1-5V setable from |
±1.000V to ±10.500V |
ranges |
Accuracy |
±0.04% f.s. |
Zero Drift |
±20 ppm/°C of f.s. |
Span Drift |
±50 ppm/°C of range |
Input Impedance |
>1 Mohm |
Input Current |
<10 nA |
4000P Current Input |
|
Input Range |
0/40-20 setable from ±1 mA to ±20 mA ranges |
Accuracy |
0.05% f.s. |
Zero Drift |
±20 ppm/°C of f.s. |
Span Drift |
±50 ppm/°C of range |
Input Resistance |
<20 ohm |
4000S Millivolt Input |
|
Input Range |
Setable range from ±30mVto ±120mV |
Accuracy |
±0.04% @ 100 mV |
Zero Drift |
±1uV°C + 20 ppm/°C of f.s. |
Span Drift |
±50 ppm/°C of f.s. |
Input Impedance |
>1000 Mohm |
Input Current |
<10nA |
General Specifications |
|
Input |
|
N.M.R.R. |
>60 dB @ 50 and 60Hz (without digital filter) |
C.M.R.R. |
>135 dB from input to supply |
Response Time |
1 second within ±0.05% |
Conversion |
|
Measuring System |
Continuous integration charge balancing converter |
Internal Resolution |
1 part over 200,000 |
Conversion Time |
Setable at 200, 400, 800,msec. |
Digital Filter |
Walking window mean setable as slow, normal or fast |
Power Supply |
|
AC Supply Voltage |
90-264 ACV @ 47-70Hz |
Power Consumption |
4 VA |
Isolation |
>2500 Vrms |
Environmental |
|
Warmup Time |
1 minute |
Operating Temperature |
-10/+60°C |
Storage Temperature |
-40/+85°C |
Humidity |
0/90% non-condensing |
Mechanical |
|
Front Protection |
IP65/NEMA4 |
Dimensions |
3/64 DIN; 0.94" x 2.83" x 4.5" (24 x 72 x 114.3 mm) |
Case Material |
Polycarbonate UL94V.2 |
Weight |
0.4 pound - 200 g |
Cut Out Dimensions |
22H x 68W mm |
Excitation Supply |
|
4000P |
24V ±5% @ 30 mA max. short circuit protected. |
4000S |
10V ±0.1% @ 30 mA max. short circuit protected and internal voltage trimming. |
Alarm Output |
|
Relay Output |
250 ACV @ 5 A/24 DCV @ 1A |
Options |
|
Option: Analog Output |
|
Current |
0/4-20mA source |
Load Resistance |
0 to 550 ohm |
Voltage |
0-10V; output impedance 10 ohm |
Accuracy |
±0.1% |
Isolation |
500Vrms |
Option: IR Probe and Setup Softwarex |
|
Option: 1/8 DIN Adapter |
|
Option: RS232 Printer Output |
|
Voltage Level |
V.24 compatible |
Baud Rate |
300, 600, 1200, 2400,4800, 9600 |
| Isolation | 200Vrms |